Plastic Tank Eductors

Available in PPL (Glass Reinforced Polypropylene) and PVDF (KYNAR®). Eductor circulation ratio of supply to discharge is 1:5

We stock PPL & PVDF materials in sizes from 1/4″ through 1-1/2″.

Plastic Tank EductorsTank Eductors are designed for “in-tank” applications. The TLM operates on the principle of flow dynamics pressurized fluid is accelerated through the nozzle to become a high velocity stream that entrains tank contents and intimately mixes with them. This combined stream exits the TLM at a high velocity creating a flow field capable of causing additional agitation and mixing the tank contents.Tank Eductor Sizing Request Form (We’ll reply with the recommended size along with price & availability)

The tank eductor’s motive fluid may come from two sources. The tank liquid may be re-circulated through the eductor via an external pump or a secondary fluid may be introduced into the tank. Gases, as well as liquids, are used as the secondary fluid. Aeration and gas dispersion for chemical reactions are common uses of gas motive systems. Liquids are typically additives to be mixed with or to dilute the tank contents.

  • Excellent resistance (no attack) to dilute and concentrated Acids, Alcohols, Bases and Mineral Oils
  • Good resistance (minor attack) to Aldehydes, Esters, Aliphatic Hydrocarbons, Ketones and Vegetable Oils
  • Limited resistance (moderate attack and suitable for short term use only) to Aromatic and Halogenated Hydrocarbons and Oxidizing Agents.

Design Ratings:

  • Maximum Temperature: 220°F (104°C)
  • Minimum Temperature: 0°F (-18°C)

Application Data:

  • Minimum Inlet Pressure: 10 psig (70 kPaG)
  • Maximum Inlet Pressure: 100 psig (690 kPaG)

Most efficient operation takes place when inlet pressure is within the range of 20 to 70 psig (140 to 480 kPaG). Four gallons of tank contents can be mixed for every gallon of operating fluid. For inlet pressures outside this range, tank contents mixed will be reduced.

A TLM can be mounted in any position. The supply line and manifold piping to multiple TLM’s must be sized to supply uniform pressure to each TLM.  It is important that the TLM be positioned within the tank so as to insure the free flow of liquid to be mixed into and out of the unit(s). The greatest agitation occurs within the discharge plume; therefore, the discharge end should be aimed towards the most remote part of the tank. On the other hand, the intake end of the unit must be far enough from the tank corner or wall to allow the free flow of liquid into the suction openings.

Tank shape and size influence the placement and number of TLM’s required to maintain even agitation or temperature distribution.  With no corners to impede liquid flow, the liquid circulates evenly.

In a cylindrical, square, or rectangular tank, the angular intersection of surfaces can interrupt liquid flow patterns and cause liquid stagnation in these areas.  Whenever the ration of length to diameter of the tank is greater than 2:1 (such as tank trucks or railroad cars), it is recommended that multiple TLM’s be used.

In tanks where a critical velocity must be maintained on the tank bottom, a slight downward angle of the TLM’s can be helpful.

 

KYNAR® (PVDF) is a high molecular weight thermoplastic polymer with excellent chemical inertness. It is highly resistant to oxidizing agents and halogens and is almost completely resistant to allphatic, aromatics, alcohols, acids and chlorinated solvents. It is resistant to most acids and bases.  Mechanically strong. High dielectric strength. Thermally stable. Resistant to low temperatures. Stable to ultraviolet and extreme weather conditions. Self-extinguishing and non-toxic.

Quick Facts:

  • Maximum recommended temperature: 250° F
  • Thermal conductivity (ASTM C 177) : 1.32 Btu-inch/hr-ft~2- ° F
  • Specific heat : 0.23 Btu/lb- ° F
  • Coefficient of linear thermal expansion (ASTM D 696) : 7.1×10~5
  • Applicable temperature range for thermal expansion : 50-300° F

Mechanical Properties:

  • Specific gravity (ASTM D 792) : 1.78
  • Tensile strength, Ultimate (ASTM D 638) : 7,800 p.s.i.
  • Elongation at break (ASTM D 638) : 80%
  • Tensile modulus (ASTM D 638) : 3.5×10~5 p.s.i.
  • Rockwell hardness (ASTM D 785) : R100
  • Impact strength (73° F) (ASTM D 256) (notched) : 3.0 ft-lb/inch
  • Flexural strength (ASTM D 790) : 10,750 p.s.i.
  • Flexural modulus (ASTM D 790) : 3.3x 10~5 p.s.i.
  • Wear factor against steel 40 psi 50 fpm : 1000×10~10
  • Coefficient of friction 40 psi 50 fpm : 0.24 Dynamic

 

Plastic Tank Eductors

Model PPL KYNAR Pipe Size Dim L Dim D
TLM-02-00 -PP -KN 1/4″ 3-1/8″ 1-1/2″
TLM-03-00 -PP -KN 3/8″ 4-1/2″ 2-1/8″
TLM-06-00 -PP -KN 3/4″ 6-3/8″ 3″
TLM-08-00 -PP -KN 1″ 8-1/2″ 3-3/4″
TLM-12-00 -PP -KN 1-1/2″ 9-7/8″ 4-5/8″

 

TLM Peformance Table

Model Free Passage 10 PSI 15 PSI 20 PSI 25 PSI 30 PSI 35 PSI 40 PSI 50 PSI
TLM-02-00 0.188 3.2 3.9 4.5 5.0 5.5 5.9 6.3 7.1
TLM-03-00 0.288 7.5 9.2 10.6 11.9 13.0 14.0 15.0 16.8
TLM-06-00 0.386 13.5 16.5 19.1 21 23 25 27 30
TLM-08-00 0.481 21 26 30 33 36 39 42 47
TLM-12-00 0.612 33 40 47 52 57 62 66 74